3.4.8 Replacing SMB battery
Continued
RMU 101
A
xx1300000339
A
B
Required equipment
There are two variants of SMB units and batteries. One with 2-pole battery contact
and one with 3-pole battery contact. The variant with the 3-pole battery contact
has longer lifetime for the battery.
It is important that the SMB unit uses the correct battery. Make sure to order the
correct spare parts. Do not replace the battery contact!
Equipment
SMB battery pack
Standard toolkit
Circuit diagram
Continues on next page
182
B
SMB battery (3-pole battery contact)
Battery cover
Note
Note
Battery includes protection circuits. Replace it only with given
spare part no. or an ABB approved equivalent.
See
Spare part lists on page
Content is defined in section