4 Repair
4.3.4 Replacing SMB unit
Continued
6
7
8
9
10
11
236
Action
Put back the cable harness in the base and
refit the bracket on the distance screws.
Note
Use caution when performing this procedure
order not to damage cables or other com-
ponents!
Secure the battery cable with cable straps.
Use caution when pushing the base cover
into position while at the same time check-
ing that no cables are damaged.
Refit the base cover.
Recalibrate the robot.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
- First test run may cause injury or damage!
on page
50.
© Copyright 2009-2015 ABB. All rights reserved.
Note
See the figure in:
Location of SMB unit on page 232
xx0800000456
Parts:
A: Attachment screws (6 pcs)
B: Base cover
C: Base
Calibration is detailed in a separate calib-
ration manual enclosed with the calibra-
tion tools.
General calibration information is included
in section
Calibration information on
page
361.