Product manual - IRB 2600
3HAC035504-001 Revision: G
Action
Apply load F=40N downwards at a distance
B from the rotation center of axis 6.
Remove the load and measure the play by
reading the dial indicator.
Turn axis 6 to +180°.
Repeat step 9 to step 12.
© Copyright 2009-2015 ABB. All rights reserved.
4.4.7 Measuring the play, axis 6 (ID upper arm)
Info
A
B
xx1100000694
A 100 mm (dial indicator)
B 140 mm
The maximum play allowed is:
IRB 2600ID - 15/1.85: 0.20 mm
IRB 2600ID - 8/2.00: 0.22 mm