4 Repair
4.7.3 Replacing motor axis 5 - IRB 2600ID
Continued
14
15
16
Continues on next page
322
Action
Apply flange sealing (Loctite 574) on the
surface shown in the figure.
Note
Do not apply flange sealing on the surfaces
where Sikaflex 521FC shall be applied!
See figure!
Refit the cover with two inner attachment
screws.
Refit the bracket with the remaining attach-
ment screws.
© Copyright 2009-2015 ABB. All rights reserved.
Info
xx1000001003
Parts:
A Surface where Sikaflex 521FC shall
be applied
B Surface where Loctite 574 shall be
applied.
xx1000000879
Parts:
A Attachment screws (5 pcs)
B Mechanical stop
C O-ring
D Distance ring
E Bracket
F Cover
See figure above.
Product manual - IRB 2600
3HAC035504-001 Revision: G