ABB IRB 2600 Product Manual page 328

Hide thumbs Also See for IRB 2600:
Table of Contents

Advertisement

4 Repair
4.7.4 Replacing motor axis 6 and wrist unit - IRB 2600ID
Continued
9
10
11
12
13
Continues on next page
328
Action
Fit two short screws in the holes for the at-
tachment screws in order to temporarily
secure that the cover is not opened.
Disconnect the cables R4.MP6 and R4-FB6
to motor axis 6.
Put the wrist on a work bench.
Note
Do not move the gears in the wrist when the
motor is removed! When refitting the motor
the gears in the wrist shall be in the same
position as they were before the removal.
Remove the cable protection by removing
the nuts securing it.
© Copyright 2009-2015 ABB. All rights reserved.
Info
xx1000000932
Parts:
A: Short screws (2 pcs)
R4.MP6
R4.FB6
xx1400002575
xx1000000931
Parts:
A: Cable protection
B: Nuts (2 pcs)
C: Connector motor axis 6