ABB IRB 2600 Product Manual page 216

Hide thumbs Also See for IRB 2600:
Table of Contents

Advertisement

4 Repair
4.3.2 Refitting the complete cable harness
Continued
11
12
13
14
15
Continues on next page
216
Action
Secure the bracket on the distance screws.
Reconnect connectors on the brake release
unit:
X8
X9
X10
Refit the R1.SMB-connector on the bracket.
Tip
Use a deep well hexagon socket, width 30
mm (like the ones used for spark plugs, or
similar).
xx1200000888
Refit the air hose connector on the bracket.
Note
Check that there is no leakage from the air
hose.
Reconnect the battery cable.
© Copyright 2009-2015 ABB. All rights reserved.
Note
D
xx1200000887
A Base
B Distance screw
C Attachment screw
D Bracket
D
C
xx1200000889
A Thin nut, width 30 mm
B R1.SMB
C Bracket
D Air connector
Product manual - IRB 2600
3HAC035504-001 Revision: G
A
B
C
A
B

Hide quick links: