ABB IRB 2600 Product Manual page 279

Hide thumbs Also See for IRB 2600:
Table of Contents

Advertisement

Required equipment
Equipment
Lower arm
Standard toolkit
Other tools and procedures may be re-
quired. See references to these procedures
in the step-by-step instructions below.
Removing the lower arm
Use this procedure to remove the lower arm.
The robot lower arm weighs 35 kg.
All lifting accessories used must be sized accordingly!
1
2
3
4
Product manual - IRB 2600
3HAC035504-001 Revision: G
CAUTION
Action
Move the robot to the position shown in the
figure.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Remove the cable package from all axes
except in the base.
Secure the upper arm with a roundsling in
an overhead crane.
© Copyright 2009-2015 ABB. All rights reserved.
4.5.1 Replacing the lower arm
Note
For spare parts no. see Spare parts - Lower
arm and motors in Product manual, spare
parts - IRB 2600.
Content is defined in section
on page
383.
These procedures include references to the
tools required.
Note
xx0800000336
How to remove the cable package in
frame, lower arm and armhouse is de-
scribed in sections:
Removing cable harness in frame
on page 202
Removing cable harness in lower
arm and armhouse on page 203
Continues on next page
4 Repair
Continued
Standard tools
279