NTP-G55 Verify the Optical Receive Power

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
Using an optical power meter, check the receive optical power on both ends of the span:
Step 2
a.
b.
If the optical power is too low (indicated by an alarm or APC out of range or skipped condition), check
Step 3
the fiber connections as appropriate to your node configuration:
If the power coming from the AD-xC-xx.x card is higher than required, put an external optical attenuator
Step 4
before the client interface input in order to meet the power requirement.
If the power coming from the 32DMX-O card is higher or lower than required, you can regulate the VOA
Step 5
in CTC.
November 2004
This procedure verifies the optical receive power.
Optical power meter
DLP-G46 Log into CTC, page 2-25
As needed
Onsite
Provisioning or higher
"DLP-G46 Log into CTC" task on page 2-25
Identify a transmit port on an AD-xC-xx.x, 32DMX-O, 32DMX, or 4MD card in the node that you
want to test and connect it to the optical power meter.
Read the values displayed on the optical power meter. These values must be consistent with the data
provided by the MetroPlanner installation file, +/– 1 dB. To view MetroPlanner values, click the
Provisioning > WDM-ANS > Provisioning tabs. For 32DMX-O and 32DMX cards, the values are
listed in the Channel x Drop Power field (dwdm.rx.power.DropChxW/E) where x = 1 to 32. For
OADM cards, the fields are listed in the Band [x] Drop (dwdm.rx.power.DropBxW/E) field where
x = 1 to 8.
For information about using an optical power meter, refer to the optical power meter user
Note
guide.
Check the fiber connections between the OPT-BST amplifier or the OSC-CSM card and the
OPT-PRE amplifier or the next OADM card.
Check the fiber connections between the OADM cards and if needed clean the connectors. See the
"NTP-G115 Clean Fiber Connectors" procedure on page
From the 32DMX-O or 32DMX card view, choose the Provisioning > Optical Chn > Parameters
tabs. The VOA columns including the VOA power and attenuation reference points can be manually
set according to your site plan.
at an ONS 15454 on the network.
11-32.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
NTP-G55 Verify the Optical Receive Power
3