Chapter 7
Manage Alarms
If the card is a 4MD card, click the Provisioning > Optical Chn > Alarm Profiles >
Alarm Profile Editor tabs or the Provisioning > Optical Band > Alarm Profiles >
Alarm Profile Editor tabs.
If the card is an OPT-PRE or OPT-BST card, click the Provisioning > Optical Line >
Alarm Profiles > Alarm Profile Editor tabs or the Provisioning > Opt. Ampli. Line >
Alarm Profiles > Alarm Profile Editor tabs.
If the card is an AD-1C, AD-2C, or AD-4C card, click the Provisioning > Optical Line >
Alarm Profiles > Alarm Profile Editor tabs or the Provisioning > Optical Chn >
Alarm Profiles > Alarm Profile Editor tabs.
If the card is an AD-1B or AD-4B card, click the Provisioning > Optical Line > Alarm Profiles >
Alarm Profile Editor tabs or the Provisioning > Optical Band > Alarm Profiles >
Alarm Profile Editor tabs.
If you want to create a new profile based on the default profile in use, click New. Continue with
Step 4
If you want to create a profile using an existing profile located on the node, click Load and From Node
Step 5
in the Load Profiles dialog box.
Click the node name you are logged into in the Node Names list.
a.
Click the name of an existing profile in the Profile Names list, such as Default. Continue with
b.
Step
If you want to create a profile using an existing profile located in a file that is stored locally or on a
Step 6
network drive, click From File in the Load Profiles dialog box.
a.
Click Browse.
b.
Navigate to the file location in the Open dialog box.
Click Open.
c.
Note
Note
Click OK.
Step 7
The alarm severity profile appears in the Alarm Profiles window.
Note
Right-click anywhere in the profile column to view the profile editing shortcut menu. (Refer to
Step 8
for further information about the Default profile.)
Click Clone in the shortcut menu.
Step 9
Tip
November 2004
7.
The Default alarm profile list contains alarm and condition severities that correspond when
applicable to default values established in Telcordia GR-253-CORE.
All default or user-defined severity settings that are Critical (CR) or Major (MJ) are demoted to
Minor (MN) in Non-Service-Affecting (NSA) situations as defined in Telcordia GR-474.
The alarm profile list contains a master list of alarms that is used for a mixed node network.
Some of these alarms might not be used in all ONS nodes.
To see the full list of profiles, including those available for loading or cloning, click Available.
You must load a profile before you can clone it.
DLP-G121 Create a New or Cloned Alarm Severity Profile
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
Step
10.
Step 11
7-19