Ntp-G68 Create, Download, And Assign Alarm Severity Profiles; Figure 7-8 Shelf Lcd Panel - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 7
Manage Alarms
Step 4
Press the Status button to see a summary of alarms and severities against the slot. For example, you
might see "Slot-3 Alm CT:0 MJ:1 MN:2." This means that there are no critical alarms, one major alarm,
and two minor alarms against the slot.
If you want to view the alarms against a port on the card, such as Port 3 of the OC-3 card you viewed
Step 5
previously, press the Port button until you see "Port-3 Status=Alm Ct."
Press Status to view alarm count against the port. You will see a message similar to "Port-3 Alm CT:0
Step 6
MJ:1 MN:0." This means that there is one major alarm against this port.
Figure 7-8
Figure 7-8
To return to the previous view from the Port screen, continue to press Port until the display cycles
through all the ports on the slot.
To return to the node menu from the Slot screen, press Slot until you cycle through all the slots and see
"Node."
If you do not press any buttons, the LCD will return to its default display with the node name. However,
if you did not cycle through the options to return to the node status, you will see the slot or port where
you last checked status.
Note
Stop. You have completed this procedure.

NTP-G68 Create, Download, and Assign Alarm Severity Profiles

Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
November 2004
shows the shelf LCD panel.
Shelf LCD Panel
Slot
Status
FAN FAIL
CRIT
MAJ
A blank LCD results when the fuse on the alarm interface panel (AIP) board has blown. If this
occurs, log into http://www.cisco.com/tac for more information or log into
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml to obtain a directory of
Cisco TAC toll-free numbers for your country.
Use this procedure to create a customized alarm profile at the network,
node, or card level. This procedure also provides links to tasks that
describe how to assign custom severities individually to each port, card, or
node, and to delete alarm profiles.
None
As needed
Onsite or remote
Provisioning or higher
NTP-G68 Create, Download, and Assign Alarm Severity Profiles
Port
8/18/03
04.06-002L-10
MIN
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
24˚C
7-17

Advertisement

Table of Contents
loading

Table of Contents