Chapter 10
Change Card Settings
Table 10-53 MXP_MR_2.5G and MXPP_MR_2.5G Muxponder Card Line Threshold Settings (continued)
RMON Thresholds
FC
UAS
1. RMON thresholds apply to all data types. A PPM must be defined for the port to be able to define a line threshold. This only
2. SONET thresholds apply only to trunk ports (9 for MXP_MR_2.5G or 9 to 10 for MXPP_MR_2.5G).
Click Apply.
Step 4
Return to your originating procedure (NTP).
Step 5

DLP-G241 Change Optical Thresholds Settings for MXP_MR_2.5G

and MXPP_MR_2.5G Cards

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
In node view, double-click the MXP_MR_2.5G or MXPP_MR_2.5G card where you want to change the
optical threshold settings.
Click the Provisioning > Optics Thresholds tabs.
Step 2
Modify any of the settings described in
Step 3
September 2004
DLP-G241 Change Optical Thresholds Settings for MXP_MR_2.5G and MXPP_MR_2.5G Cards
1
(Line only.) Failure count.
(Line only.) Unavailable seconds.
applies to client Ports 1 to 8 and GFP facilities (trunk Port 9 for MXP_MR_2.5G or trunk Ports 9 to 10 for MXPP_MR_2.5G).
This task changes the optical threshold settings for MXP_MR_2.5G and
MXPP_MR_2.5G muxponder cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
Numeric. Can be set for Near End or Far
End, for 15-minute or one-day intervals
for Line only. Select the bullet and click
Refresh.
Numeric. Can be set for Near End or Far
End, for 15-minute or one-day intervals,
for Line only. Select the bullet and click
Refresh.
Table
10-43.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
10-75