Turn Up a Node
Insert the front door into the hinges on the shelf assembly.
Step 1
Attach one end of the ground strap terminal lug (72-3622-01) to the male stud on the inside of the door.
Step 2
Attach and tighten the #6 Kepnut (49-0600-01) using the open-end wrench
Figure 3-19 Installing the Door Ground Strap Retrofit Kit
Step 3
Attach the other end of the ground strap to the longer screw on the fiber guide.
Attach the lock washer.
a.
Attach the terminal lug.
b.
Using the open-end wrench, attach and tighten the #4 Kepnut (49-0337-01) on the terminal lug.
c.
Note
Replace the left cable-routing channel.
Step 4
Using a Phillips screwdriver, insert and tighten the screws for the cable-routing channel.
Step 5
Figure 3-20
September 2004
To avoid interference with the traffic (line) card, make sure the ground strap is in a flat
position when the door is open. To move the ground strap into a flat position, rotate the
terminal lug counterclockwise before tightening the Kepnut.
shows the shelf assembly with the front door and ground strap installed.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
NTP-G40 Replace the Front Door