Dlp-G213 Change Optical Channel Optics Thresholds For The 32Wss Card; Table 10-15 32Wss Card Optical Channel Optics Threshold Settings - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 10
Change Card Settings

DLP-G213 Change Optical Channel Optics Thresholds for the 32WSS Card

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click the 32WSS card where you want to change the optical channel optics
Step 1
threshold settings.
Click the Provisioning > Optical Chn: Optical Connector tab for one of the four optical channel:
Step 2
optical connector tabs (1 to 4) that are available.
Step 3
Click the Optics Thresholds tab to display the warnings thresholds settings for each port.
Step 4
Modify any of the settings described in

Table 10-15 32WSS Card Optical Channel Optics Threshold Settings

Parameter Description
Port
opwrMin
(dBm)
opwrMin
(dBm)
Select the threshold alert type by clicking either the Warning or the Alarm radio button.
Step 5
Select the warning threshold interval by selecting either the 15 Min or 1 Day radio button.
Step 6
Step 7
Click the Refresh button.
Step 8
Return to your originating procedure (NTP).
September 2004
This task changes the optical channel optics threshold settings for the
32WSS card.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
Display only. Port designation information.
Each Optical Channel has a unique RX and a
PT port in this field. For example, the first two
ports of Optical Ch: Optical Connector 1 are
designated as 1 CHAN-16-1-RX and
33 CHAN-16-1-PT. These two corresponding
ports are shown in the 32WSS display
windows in the top row as ADD RX Port 01
and PT Port 33.
Sets the warning thresholds minimum value
(dBm).
Sets the warning thresholds maximum value
(dBm).
DLP-G213 Change Optical Channel Optics Thresholds for the 32WSS Card
Table
10-15.
Options
User-defined value. Typically a negative
optical power setting.
User-defined value. Typically a positive
optical power setting.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7