Alarm Monitoring and Management

Figure 20-6 External Alarms and Controls Using a Virtual Wire

Smoke
detector
When using AIC virtual wires, you can:

20.8 Audit Trail

The Cisco ONS 15454 maintains a Telcordia GR-839-CORE-compliant audit trail log that resides on the
TCC2. This record shows who has accessed the system and what operations were performed during a
given period of time. The log includes authorized Cisco logins and logouts using the operating system
command line interface, CTC, and TL1; the log also includes FTP actions, circuit creation/deletion, and
user/system generated actions.
Event monitoring is also recorded in the audit log. An event is defined as the change in status of an
element within the network. External events, internal events, attribute changes, and software
upload/download activities are recorded in the audit trail.
September 2004
Smoke
detector
Virtual Wire #1
ONS 15454
Node 4
Virtual Wire #1
Assign different external devices to the same virtual wire.
Assign virtual wires as the trigger type for different external controls.
Bell
Virtual Wire #1 is
external control
trigger
ONS 15454
Node 1
ONS 15454
Node 2
ONS 15454
Node 3
Smoke
detector
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
20.8 Audit Trail
Virtual Wire #1
Smoke
detector
Virtual Wire #1
= External alarm
= External control