NTP-G37 Run Automatic Node Setup

Step 3
Click Delete.
Return to your originating procedure (NTP).
Step 4
NTP-G37 Run Automatic Node Setup
Purpose
Tools/Equipment
Prerequisite Procedures An Installation Parameters file for the node exported from
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
node setup. If you are already logged in, continue with
Click the Alarms tab.
Step 2
a.
b.
Complete the
Step 3
Click the Port Status tab. Click Launch ANS.
Step 4
Step 5
In the Apply Launch ANS dialog box, click Yes. ANS adjusts the values of the VOAs to equalize the
per-channel power at the amplifier level.
In the Launch ANS confirmation dialog box, click OK.
Step 6
Verify that one of the following statuses appears in the Link Status column for all ports. If so, continue
Step 7
with
If one of the following statuses is shown, complete the provided instructions:
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
3-58
This procedure runs the CTC DWDM automatic node setup (ANS)
function. ANS updates the values of the variable optical attenuators
(VOAs) to equalize the per-channel power at the amplifier level.
None
Cisco MetroPlanner.
NTP-G36 Calculate Cable Connections, page 3-56
Required
Onsite or remote
Superuser
"DLP-G46 Log into CTC" task on page 2-25
Verify that the alarm filter is not on. See the
as necessary.
Verify that no unexplained alarms appear on the network. If alarms appear, investigate and resolve
them before continuing. Refer to the Cisco ONS 15454 SONET and DWDM Troubleshooting Guide
for procedures.
"DLP-G74 Import a Cisco MetroPlanner Configuration File" task on page
Step
8.
Success - Changed—The parameter setpoint was recalculated successfully.
Success - Unchanged—The parameter setpoint did not need recalculation.
Not Applicable—The parameter setpoint does not apply to this node type.
Fail - Out of Range—The calculated setpoint is outside the expected range. Repeat the
Calculate Cable Connections" procedure on page 3-56
provisioned correctly, paying attention to connections that require manual provisioning.
at the node where you want to run automatic
Step
2.
"DLP-G128 Disable Alarm Filtering" task on page 7-32
to verify that all connections have been