DLP- G19 Turn On and Verify Office Power

NTP-G9 Install the Alarm Expansion Panel (ANSI Only)

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The AIC-I card provides direct alarm contacts (external alarm inputs and external control outputs). In
Note
the ANSI shelf, these AIC-I alarm contacts are routed through the backplane to wire-wrap pins
accessible from the back of the shelf. When you install an AEP, the direct AIC-I alarm contacts cannot
be used. Only the AEP alarm contacts can be used.
Step 1
Remove the two backplane screws. Replace the two screws with standoffs. Insert the longer standoff on
the left, and the shorter standoff on the right
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
1-44
This procedure installs an AEP onto the 15454-SA-ANSI or 15454-SA-HD
shelf backplane. The AEP provides alarm contacts (32 inputs, 16 outputs)
in addition to the 16 provided by the AIC-I card. Typically, the AEP is
preinstalled when ordered with the ONS 15454; however, the AEP can be
ordered separately. The AIC-I card must be installed before you can
provision the alarm contacts enabled by the AEP.
#2 Phillips screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
Wire wrapper
6-pair #29 AWG double-shielded cable
Standoffs (4)
DLP-G13 Remove the Lower Backplane Cover, page 1-26
As needed
Onsite