Dlp-G83 Verify The Osc-Csm Power-Oadm Nodes; Dlp-G84 Verify The Osc-Csm Incoming Power - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 4
Perform Node Acceptance Tests
Note
Return to your originating procedure (NTP).
Step 4
DLP-G83 Verify the OSC-CSM Power—OADM Nodes
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Display the OSC-CSM card in card view.
Step 1
Click the Provisioning > Optical Line > Parameters tabs.
Step 2
Change the Admin State for Port 1 to OOS,MT/Locked,maintenance.
Step 3
Verify that the Power value for Port 3 is higher than the default no-power value of –30 dBm. The
Step 4
calculated expected power value for Port 3 is:
Pout COM TX of last AD-xy-xx.x – IL02 OSC-CSM (COM RX > LINE TX) – 10 dB (bulk attenuator)
Double-check the value.
Step 5
Note
Return to your originating procedure (NTP).
Step 6

DLP-G84 Verify the OSC-CSM Incoming Power

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Display the OSC-CSM card in card view.
Step 1
September 2004
Actual output power is affected by many factors. Always consider the calculated expected power
to be a general guideline and not a precise value.
This task verifies OSC-CSM card.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser only
Actual output power is affected by many factors. Always consider the calculated expected power
to be a general guideline and not a precise value.
This task verifies OSC-CSM card incoming power.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser only
DLP-G83 Verify the OSC-CSM Power—OADM Nodes
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
4-25