When a software reset is performed on an active TCC2, the AIC-I card goes through an initialization
Note
process and also resets. The AIC-I card reset is normal and happens each time an active TCC2 card goes
through a software-initiated reset.
Click the Alarms tab.
Step 1
a.
b.
In node view, right-click the TCC2 card to reveal a drop-down list.
Step 2
Step 3
Click Reset Card.
Step 4
Click Yes when the confirmation dialog box appears.
Click OK when the "Lost connection to node, changing to Network View" dialog box appears.
Step 5
Note
Confirm that the TCC2 card LED is amber (standby).
Step 6
Return to your originating procedure (NTP).
Step 7

DLP-G251 Reset DWDM Cards Using CTC

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
Warning
circuitry could constitute an energy hazard.
September 2004
Verify that the alarm filter is not on. See the
as necessary.
Verify that no unexplained alarms appear on the network. If alarms appear, investigate and resolve
them before continuing. Refer to the Cisco ONS 15454 SONET and DWDM Troubleshooting Guide
for procedures.
For LED behavior during a TCC2 reboot, see
"DLP-G128 Disable Alarm Filtering" task on page 7-32
Table 3-1 on page
This task resets the OSCM, OSC-CSM, 32MUX-O, 32DMX-O,
32DMX, 32WSS, OPT-BST, OPT-PRE, AD-xC.xx.x, AD-xB.xx.x,
TXP, and MXP cards using CTC.
None
NTP-G30 Install the DWDM Cards, page 3-26
NTP-G32 Install the Transponder and Muxponder Cards, page 3-30
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
DLP-G251 Reset DWDM Cards Using CTC
3-12.
11-11

Advertisement

Table of Contents
loading

Table of Contents