Cisco ONS 15454 DWDM Installation And Operation Manual page 247

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 4
Perform Node Acceptance Tests
Step 10
Change the Port 1 Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Change the Port 33 Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 11
Click the Maintenance tab.
Step 12
For Channel #1, change Operating Mode to Add Drop.
Step 13
Click the Provisioning > Optical Chn > Parameters tabs.
Step 14
Verify that the Port 1 power level reaches the provisioned VOA Power Ref setpoint.
Step 15
Display the OPT-BST card (if present) in card view.
Step 16
Click the Provisioning > Optical Chn > Parameters tabs.
Step 17
Change the Port 1 Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 18
Display the OPT-PRE card in card view.
Step 19
Click the Provisioning > Optical Chn > Parameters tabs.
Step 20
Change the Port 1 Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 21
Display the 32-DMX in card view.
Step 22
Click the Provisioning > Optical Chn > Parameters tabs.
Step 23
Change the Port 33 Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 24
Note
If an OPT-BST card is installed, complete the
Step 25
Power" task on page 4-22
Complete the
Step 26
OPT-PRE to ensure that the amplifier is working properly.
Step 27
Complete the
ensure that the card is powered correctly.
Restore the default admin states to the 32WSS, OPT-BST, OPT-PRE, and 32DMX ports that were
Step 28
changed to OOS,MT/Locked,maintenance in Steps 10, 11, 18, 21, and 24.
Repeat Steps
Step 29
behavior of all variable optical attenuators (VOAs) inside the 32WSS and 32DMX cards.
Remove the loopback created in
Step 30
Complete the
Step 31
configuration.
Step 32
Click the Alarms tab.
Verify that the alarm filter is not on. See the
a.
as necessary.
Verify that no unexplained alarms appear on the network. If alarms appear, investigate and resolve
b.
them before continuing. Refer to the Cisco ONS 15454 SONET and DWDM Troubleshooting Guide
for procedures.
Stop. You have completed this procedure.
September 2004
NTP-G42 Perform the Terminal Node with 32WSS and 32DMX Cards Acceptance Test
The tunable laser minimum output optical power (Pout) must be 6 dBm. If the output power is
lower than the specified value, the 32MUX-O card might not reach the provisioned setpoint.
on the OPT-BST to ensure that the amplifier is working properly.
"DLP-G80 Verify the OPT-PRE Amplifier Laser and Power" task on page 4-23
"DLP-G81 Verify the 32DMX-O or 32DMX Power" task on page 4-24
7
through
28
for the remaining 32 wavelengths of the 100-Ghz grid to verify the correct
Step
"NTP-G37 Run Automatic Node Setup" procedure on page 3-58
"DLP-G79 Verify the OPT-BST Amplifier Laser and
6.
"DLP-G128 Disable Alarm Filtering" task on page 7-32
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
on the
on the 32DMX to
to restore the original
4-5

Advertisement

Table of Contents
loading

Table of Contents