Chapter 3
Turn Up a Node
1
West DCU TX to west OPT-PRE DC RX
2
West DCU RX to west OPT-PRE DC TX
3
West OPT-BST COM TX to west OPT-PRE COM RX
4
West OPT-BST COM RX to west AD-1C-xx.x COM TX
5
West OPT-PRE COM TX to west AD-1C-xx.x COM RX
6
West AD-1C-xx.x (15xx.xx) RX to west TXP_MR_2.5G DWDM TX
7
West AD-1C-xx.x (15xx.xx) TX to west TXP_MR_2.5G DWDM RX
8
West AD-1C-xx.x EXP TX to east AD-1C-xx.x EXP RX
9
West AD-1C-xx.x EXP RX to east AD-1C-xx.x EXP TX
10
East TXP_MR_2.5G DWDM RX to east AD-1C-xx.x (15xx.xx) TX
11
East TXP_MR_2.5G DWDM TX to east AD-1C-xx.x (15xx.xx) RX
12
East AD-1C-xx.x COM RX to OPT-PRE COM TX
13
East AD-1C-xx.x COM TX to OPT-BST COM RX
14
East OPT-PRE COM RX to east OPT-BST COM TX
15
East DCU TX to east OPT-PRE DC RX
16
East DCU RX to east OPT-PRE DC TX
1. If a DCU is not installed, a 5 dB attenuator loop must be installed between the OPT-PRE DC ports.
Figure 3-16
September 2004
1
1
1
1
shows an example of a passive OADM node with two AD-1C-xx.x cards installed.
DLP-G70 Install Fiber-Optic Cables for an Amplified or Passive OADM Node