Roadm Power Equalization Monitoring; Span Loss Verification; Figure 15-16 Power Monitoring Subtab - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

15.3 ROADM Power Equalization Monitoring

Table 15-1 APC-Managed Parameters (continued)
Card
AD-4C-xx.x
32-DMX
15.3 ROADM Power Equalization Monitoring
Reconfigurable OADM (ROADM) nodes allow you to monitor the 32WSS card equalization functions
on the Maintenance > DWDM > Power Monitoring subtab
channel power (Padd), the express or pass-through (Ppt) power and the power level at output (Pout).

Figure 15-16 Power Monitoring Subtab

15.4 Span Loss Verification

Span loss measurements can be performed from the Maintenance > DWDM > WDM Span Check subtab
(Figure
"Span Loss Out of Range" condition is raised when the measured span loss is higher than the maximum
expected span loss. It is also raised when the measured span loss is lower than the minimum expected
span loss and the difference between the minimum and maximum span loss values is greater than 1 dB.
The minimum and maximum expected span loss values are calculated by Cisco MetroPlanner for the
network and imported into CTC. However, you can manually change the minimum and expected span
loss values.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
15-18
Port
LINE-1-TX
CHAN-i-TX
LINE-1-TX
15-17). The CTC span check compares the far-end OSC power with the near-end OSC power. A
Parameters
VOA Target Attenuation
VOA Target Attenuation
(Figure
Chapter 15
DWDM Node Reference
15-16). The tab shows the input
September 2004

Advertisement

Table of Contents
loading

Table of Contents