Chapter 3
Turn Up a Node
Step 7
Complete the
require manual provisioning. (Connections that require manual creation are indicated by a "Yes" in the
Cisco MetroPlanner connections file Manually Set column.) If you need to delete a connection, complete
the
Step 8
Continue with the
Stop. You have completed this procedure.

DLP-G72 Create a DWDM Connection

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, click the Provisioning > WDM-ANS > Connections tabs.
Step 1
Click the Create button.
Step 2
In the Create Optical Link dialog box, choose the From and To slots and ports from the drop-down lists.
Step 3
If the connection is unidirectional, uncheck the bidirectional check box.
Step 4
Click OK. The new connection appears in the Connections table, but its State is "Uncommitted."
Step 5
Step 6
If you need to create additional connections, repeat Steps
Step 7
Click the new connection in the table. Click the Commit button. The connection state changes to
"Connected."
Return to your originating procedure (NTP).
Step 8

DLP-G73 Delete a DWDM Connection

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
In node view, click the Provisioning > WDM-ANS > Connection tabs.
Step 2
Click the connection you want to delete.
September 2004
"DLP-G72 Create a DWDM Connection" task on page 3-57
"DLP-G73 Delete a DWDM Connection" task on page 3-57
"NTP-G37 Run Automatic Node Setup" procedure on page
This task creates a DWDM connection.
None
DLP-G46 Log into CTC, page 2-25
Required
Onsite or remote
Superuser
This task deletes a DWDM connection.
None
DLP-G46 Log into CTC, page 2-25
Required
Onsite or remote
Superuser
2
through
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
DLP-G72 Create a DWDM Connection
for any connections that
3-58.
5
for each new connection.