14.7.4.4 Power Monitoring

Physical photodiodes P1 through P4, and virtual photodiodes V1 and V2 monitor the power for the
AD-1B-xx.x card. The returned power level values are calibrated to the ports as shown in

14.7.4.5 AD-1B-xx.x Card-Level Indicators

The AD-1B-xx.x card has three card-level LED indicators, described in

Table 14-43 AD-1B-xx.x Card-Level Indicators

Card-Level Indicators
Red FAIL LED
Green ACT LED
Amber SF LED

14.7.4.6 AD-1B-xx.x Port-Level Indicators

You can find the status of the card port using the LCD screen on the ONS 15454 fan-tray assembly. Use
the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms
for a given port or slot. The AD-1B-xx.x has six LC-PC-II optical ports: two for add/drop channel client
input and output, two for express channel input and output, and two for communication.
December 2004

Table 14-42 AD-1B-xx.x Port Calibration

Photodiode
CTC "Type" Name
P1
P2
P3
P4
V1
V2
Description
The red FAIL LED indicates that the card's processor is not ready or that
there is an internal hardware failure. Replace the card if the red FAIL LED
persists.
The green ACT LED indicates that the AD-1B-xx.x card is carrying traffic
or is traffic-ready.
The amber SF LED indicates a signal failure. The amber SF LED also
illuminates when the transmit and receive fibers are incorrectly connected.
When the fibers are properly connected, the light turns off.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
Calibrated to Port
ADD
DROP
IN EXP
OUT EXP
IN COM
OUT COM
Table
14.7.4 AD-1B-xx.x Card
Table
14-42.
BAND RX
BAND TX
EXP RX
EXP TX
COM RX
COM TX
14-43.