Dlp-G71 Install Fiber-Optic Cables For An Roadm Node - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 3
Turn Up a Node
Note
Repeat
Step 6
Step 7
Return to your originating procedure (NTP).

DLP-G71 Install Fiber-Optic Cables for an ROADM Node

Purpose
Tools
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
To avoid error, connect fiber-optic cable so that the farthest slot to the right represents the east port, and
Note
the farthest slot to the left represents the west port. Fiber connected to an east port on one node must
plug into the west port on an adjacent node.
Refer to the Cisco MetroPlanner internal connections table for your site when completing connections.
Step 1
Before you begin connecting fiber-optic cabling for ROADM nodes, read the following rules:
Figure 3-17
September 2004
Cards display an SF LED after the OSC terminations are created (see the
Terminations and Ring ID" procedure on page
connected correctly. For example, an RX port is connected to another RX port or a TX port is
connected to another TX port.
Step 5
until you have connected the nodes according to the site plan.
This task gives instructions, rules, and examples to install fiber-optic cables
on an reconfigurable optical add/drop multiplexing (ROADM) node in a
DWDM shelf.
Fiber-optic cables
NTP-G115 Clean Fiber Connectors, page 11-32
As needed
Onsite
None
The west OPT-BST or OSC-CSM COM TX port is connected to the west OPT-PRE COM RX port.
The west OPT-BST or OSC-CSM COM RX port is connected to the west 32WSS COM TX port.
The west OPT-BST (if installed) OSC TX port is connected to the west OSCM RX port.
The west OPT-BST (if installed) OSC RX port is connected to the west OSCM TX port.
The west 32WSS EXP TX port is connected to the east 32WSS EXP RX port.
The west 32WSS EXP RX port is connected to the east 32WSS EXP TX port.
The west 32WSS DROP TX port is connected to the west 32DMX COM RX port.
The east OPT-BST or OSC-CSM COM TX port is connected to the east OPT-PRE COM RX port.
The east OPT-BST or OSC-CSM COM RX port is connected to the east 32WSS COM TX port.
The east OPT-BST (if installed) OSC TX port is connected to the east OSCM RX port.
The east OPT-BST (if installed) OSC RX port is connected to the east OSCM TX port.
The east 32WSS DROP TX port is connected to the east 32DMX COM RX port.
shows a sample amplified ROADM node with cabling.
DLP-G71 Install Fiber-Optic Cables for an ROADM Node
3-60) and transmit and receive fibers are not
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
"NTP-G38 Provision
3-53

Advertisement

Table of Contents
loading

Table of Contents