Chapter 13
Shelf Hardware Reference
Figure 13-7 ONS 15454 Two-Channel Optical Add/Drop FlexLayer Module
Front Panel
Labels are provided to show how the unit ports are mapped. It is the end user's responsibility to label the
unit for its intended use (drop or add component).
Figure 13-8
is used as a drop component. The COM-RX is mapped to Port 1, the COM-TX is mapped to Port 12, and
the two dropped channel TX ports are mapped to Ports 9 and 10. The two-percent tap MON port is
mapped to Port 6. Port 7 is not active.
Figure 13-8 Two-Channel Drop Component Connector Mapping and Labeling
Figure 13-9
is used as an add component. The COM-TX is mapped to Port 1, the COM-RX is mapped to Port 12, and
the added channels are mapped to the two RX Ports 9 and 10. The two-percent tap MON port is mapped
to Port 7. Port 6 is not active.
September 2004
shows how the connectors are mapped and labeled on the front panel when the component
2 Channel Drop Module 15216-FLB-2-XX.X
COM-RX
2% TAP
1
6
9
10
15XX.XX
15XX.XX
MON
TX
TX
shows how the connectors are mapped and labeled in the front panel when the component
COM-TX
12
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
13.4.1 FlexLayer Modules
13-13