NTP-G34 Install Fiber-Optic Cables on DWDM Cards

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated
Warning
July 26, 2001.
Class 1M laser product.
Warning
In this procedure, you will generally connect fibers in an east-to-west or west-to-east pattern. "West"
Note
refers to cards and ports in Slots 1, 2, 3, 4, 5, 6, and 8. "East" refers to cards and ports installed in Slots
10, 12, 13, 14, 15, 16, and 17.
Display your site plan in Cisco MetroPlanner, or refer to a printed copy of the MetroPlanner internal
Step 1
connections table. For information about Cisco MetroPlanner, refer to the Cisco MetroPlanner DWDM
Operations Guide.
Navigate to the Internal Connections table for the node you are provisioning
Step 2
connections table identifies the patch cord that you must cable by their end points. Position 1 identifies
the fiber start point; Position 2 indicates the fiber end point. The patch cord end points are identified by
site, slot, and port. Information provided by the Cisco MetroPlanner internal connections table includes:
September 2004
Revertive—Check this check box if you want traffic to revert to the working port after failure
conditions remain corrected for the amount of time entered in the Reversion Time field.
Reversion time—If Revertive is checked, select a reversion time from the drop-down list. The range
is 0.5 to 12.0 minutes. The default is 5.0 minutes. Reversion time is the amount of time that will
elapse before the traffic reverts to the working card. Traffic can revert when conditions causing the
switch are cleared.
This procedure installs the fiber-optic cables to DWDM cards and
dispersion compensating cards.
Fiber-optic cables
NTP-G30 Install the DWDM Cards, page 3-26
NTP-G31 Install the DWDM Dispersion Compensating Units, page 3-28
(as applicable)
As needed
Onsite
None
Site—The DWDM network site number for the node where you are provisioning the internal
connections.
IP Address—The node IP address.
NTP-G34 Install Fiber-Optic Cables on DWDM Cards
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
(Figure
3-10).The internal
3-35

Advertisement

Table of Contents
loading

Table of Contents