B.3.2 AIC Card Specifications (ANSI only)
•
•
•
•
B.3.2 AIC Card Specifications (ANSI only)
The ONS 15454 ETSI does not support the AIC card.
Note
•
•
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
B-8
Synchronization
Stratum 3, per Telcordia GR-253-CORE
–
Free running access: Accuracy +/– 4.6 ppm
–
Holdover stability: 3.7 x 10
–
Reference: External BITS, line, internal
–
Supply voltage monitoring
Both supply voltage inputs are monitored.
–
Normal operation: –40.5 to –56.7 V
–
Undervoltage: Major alarm
–
Overvoltage: Major alarm
–
Environmental
Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius)
–
Operating humidity: 5 to 95%, noncondensing
–
Power consumption: 26.00 W, 0.54 A at –48 V, 88.8 BTU/hr
–
Dimensions
–
Height: 12.650 in. (321.3 mm)
–
Width: 0.716 in. (18.2 mm)
Depth: 9.000 in. (228.6 mm)
–
Depth with backplane connector: 235 mm (9.250 in.)
–
Weight not including clam shell: 0.7 kg (1.5 lb)
–
Environmental
Operating temperature:
–
C-Temp (15454-AIC): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)
I-Temp (15454-AIC-T): –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius)
Operating humidity: 5 to 95%, noncondensing
–
Power consumption: 6.01 W, 0.12 A, 20.52 BTU/hr
–
Dimensions
Height: 12.650 in. (321.3 mm)
–
Width: 0.716 in. (18.2 mm)
–
Depth: 9.000 in. (228.6 mm)
–
Weight: 1.6 lb (0.7 kg)
–
-7
per day including temperature (< 255 slips in first 24 hours)
Appendix B
Hardware Specifications