Chapter 4
Perform Node Acceptance Tests
Note
If no channels are configured in pass-through mode, continue with
Step 8
pass-through mode, mark it and skip the related optical test for the express, add and drop sections.
Channel pass-through connections are verified separately.
Create a loopback on the west OPT-BST by connecting the LINE TX port to the LINE RX port using a
Step 9
patch cord and 10-dB bulk attenuator.
Verify that the OSC link becomes active on the west OSCM card. (The OSC termination must be already
Step 10
provisioned. If not, complete the
Step 11
If the OSC link becomes active, continue with
following steps:
Modify the OSC Fail Low thresholds. Click the Provisioning > Optical Line > Optics Thresholds
a.
tabs and change the Port 6 opwrMin (minimum power) to –40 dBm.
Modify the COM TX Fail Low Threshold. Change the Port 4 opwrMin (minimum power) to
b.
–30 dBm.
If the OSC link turns up, continue with
c.
card from the OPT-BST.
d.
Create a loopback on the OSCM card by connecting patch cable from the OSC TX port to the
OSC RX port using a 10-dB bulk attenuator.
If the OSC link turns up, replace the OPT-BST card. If the OSC link does not turn up, replace the
e.
OSCM card.
Note
If the node has express bands or channels, complete the
Step 12
Connections—OADM Node with OSCM Cards" task on page
bands or channels, continue with
If connections configured in pass-through mode are present (noted inSteps
Step 13
"DLP-G89 Verify OADM Node Pass-Through Channel Connections" task on page
with
Step 14
If connections have add/drop connections, complete the
on OADM Node with OSCM Card" task on page
Stop. You have completed this procedure.
September 2004
Configuring a channel in pass-through mode means the channel is dropped in one direction by
an AD-xC-xx.x card on one side (east or west) of the node, then added by another AD-xC x.xx
card on the opposite side in the same direction. The channel is not terminated inside the node.
Due to the OSC signal loopback, a SDCC Termination Failure alarm might be raised.
Step
14.
NTP-G48 Perform the Symmetric OADM Node with OSCM Cards Acceptance Test
"DLP-G75 Create OSC Terminations" task on page
Step
12. If the OSC link does not turn up, perform the
Step
12. If the OSC link is still down, disconnect the OSCM
"DLP-G85 Verify Express Channel
Step
13.
"DLP-G93 Verify Add and Drop Connections
4-33.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
Step
9. If a channel is configured in
3-61.)
4-26. If the node does not have express
5
and 7), complete the
4-29. If not, continue
4-17