B.5 Transponder and Muxponder Card Specifications
Table B-16 32WSS Optical Specifications (continued)
Parameter
Insertion loss
VOA dynamic range
Maximum optical
input power
The 32WSS card has the following additional specifications:
•
•
B.5 Transponder and Muxponder Card Specifications
This section provides specifications for the TXP_MR_10G, MXP_2.5G_10G, TXP_MR_2.5G,
TXPP_MR_2.5G, MXP_MR_2.5G, MXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_2.5G cards.
For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance
Information document.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
B-30
Condition
EXP RX =>
COM TX
COM RX =>
EXP TX
Add 1, 32 =>
COM TX
COM RX =>
DROP TX
EXP RX =>
COM TX
Add 1, 32 =>
COM TX
—
Environmental
Operating temperature:
–
C-Temp: –5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–
Operating humidity: 5 to 95% RH
Dimensions
Height: 12.65 in. (321.3 mm)
–
Width: 1.84 in. (46.8 mm)
–
Depth: 9.00 in. (228.6 mm)
–
Note
Min
All SOP, any
—
optical switch state,
and within whole
operating
temperature range,
connectors
included.
—
—
—
—
—
6
—
20
—
25
—
300
Appendix B
Hardware Specifications
Typical
Max
—
11.3
dB
—
1.5
dB
—
7.6
dB
—
8.5
dB
—
—
dB
—
—
dB
—
—
mW
April 2006
Units