holddown
Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
2044
®
OS for EX Series Ethernet Switches, Release 10.4
holddown seconds;
[edit logical-systems logical-system-name protocols rip],
[edit logical-systems logical-system-name routing-instances routing-instance-name protocols
rip],
[edit protocols rip],
[edit routing-instances routing-instance-name protocols rip]
Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Configure the time period the expired route is retained in the routing table before being
removed.
—Estimated time to wait before making updates to the routing table.
seconds
Range: 10 through 180 seconds
Default: 180 seconds
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring RIP Timers