In An Sfp+ Uplink Module Is Down; Troubleshooting Network Interfaces On Ex4200 Switches - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Cause
Solution
The interface on the port in which an SFP or SFP+ transceiver is installed in an SFP+ uplink
module is down
Problem
Cause
Solution
Related
Documentation

Troubleshooting Network Interfaces on EX4200 Switches

1354
®
OS for EX Series Ethernet Switches, Release 10.4
The last four built-in ports use the same ASIC as the SFP uplink module. Therefore, if
you install a transceiver in an SFP or SFP+ uplink module installed in an EX3200 switch,
a corresponding base port from the last four built-in ports is disabled.
If you need to use the disabled built-in port, you must remove the transceiver from the
SFP or SFP+ uplink module. Alternatively, you can install an XFP uplink module instead
of an SFP or SFP+ uplink module. There is no conflict between the built-in network ports
and the ports on the XFP uplink modules.
The interface on the port in which an SFP or SFP+ transceiver is installed in an SFP+
uplink module installed in an EX3200 switch is down.
When you check the status with the CLI command
user interface, the disabled port is not listed.
By default, the SFP+ uplink module operates in the 10-gigabit mode and supports only
SFP+ transceivers. The operating mode for the module is incorrectly set.
Either SFP+ or SFP transceivers can be installed in SFP+ uplink modules. You must
configure the operating mode of the SFP+ uplink module to match the type of transceiver
you want to use. For SFP+ transceivers, configure the 10-gigabit operating mode and for
SFP transceivers, configure the 1-gigabit operating mode. See "Setting the Mode on an
SFP+ Uplink Module (CLI Procedure)" on page 1343.
Troubleshooting Uplink Module Installation or Replacement on EX3200 Switches
Monitoring Interface Status and Traffic on page 1345
Configuring Gigabit Ethernet Interfaces (CLI Procedure) on page 1284
Configuring Gigabit Ethernet Interfaces (J-Web Procedure) on page 1287
Removing a Transceiver from an EX Series Switch
Uplink Modules in EX3200 Switches
EX Series Switches Interfaces Overview on page 1239
This topic provides troubleshooting information for specific problems related to interfaces
on EX4200 switches.
The interface on the port in which an SFP or SFP+ transceiver is installed in an SFP+
uplink module is down on page 1355
show interfaces ge-
or with the J-Web
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents