Complete Software Guide for Junos

shutdown-threshold

Syntax
Hierarchy Level
Release Information
Description
Default
Options
Required Privilege
Level
Related
Documentation
1692
®
OS for EX Series Ethernet Switches, Release 10.4
shutdown-threshold number;
[edit vlans vlan-name dot1q-tunneling layer2-protocol-tunneling all | protocol-name]
Statement introduced in Junos OS Release 10.0 for EX Series switches.
Specify the maximum number of Layer 2 PDUs of the specified protocol that can be
received per second on the interfaces in a specified VLAN before the interface is disabled.
Once an interface is disabled, you must explicitly reenable it using the
ethernet-switching layer2-protocol-tunneling error
remains disabled.
The shutdown threshold value must be greater than or equal to the drop threshold value.
If the shutdown threshold value is less than the drop threshold value, the drop threshold
value has no effect.
You can specify a shutdown threshold value without specifying a drop threshold value.
No shutdown threshold is specified.
number
—Maximum number of Layer 2 PDUs of the specified protocol that can be received
per second on the interfaces in a specified VLAN before the interface is disabled.
Range: 1 through 1000
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.
drop-threshold on page 1657
Example: Configuring Layer 2 Protocol Tunneling on EX Series Switches on page 1592
Configuring Layer 2 Protocol Tunneling on EX Series Switches (CLI Procedure) on
page 1614
clear
command. Otherwise, the interface
Copyright © 2010, Juniper Networks, Inc.