Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 2453

For ex series ethernet switches
Table of Contents

Advertisement

Table 308: show isis overview Output Fields (continued)
Field Name
Field Description
Maximum number of Shortest Path First calculations that can be performed in succession before the
SPF rapid runs
holddown timer begins.
Overload bit at startup
Overload bit capability is enabled.
is set
Overload high metrics
Overload high metrics capability:
Overload timeout
Time period after which overload is reset and the time that remains before the timer is set to expire.
Traffic engineering
Traffic engineering capability:
Restart
Graceful restart capability:
Restart duration
Time period for complete reacquisition of IS-IS neighbors.
Helper mode
Graceful restart helper capability:
Level
IS-IS level:
IP Protocol version 4 capability is enabled.
IPv4 is enabled
IP Protocol version 6 capability is enabled.
IPv6 is enabled
OSI CLNP Protocol capability is enabled. (J Series routers only)
CLNS is enabled
Preference value of internal routes.
Internal route
preference
Preference value of external routes.
External route
preference
Wide area metrics capability is enabled.
Wide area metrics are
enabled
Narrow metrics capability is enabled.
Narrow metrics is
enabled
show isis overview
show isis overview
Sample Output
Copyright © 2010, Juniper Networks, Inc.
enabled
enabled
1
—Level 1 information
2
—Level 2 information
user@host> show isis overview
Instance: master
Router ID: 192.168.1.220
Adjacency holddown: enabled
Maximum Areas: 3
LSP life time: 65535
Attached bit evaluation: enabled
Chapter 80: Operational Commands for Layer 3 Protocols
enabled
or
disabled
.
or
disabled
.
or
disabled
.
enalbed
or
disabled
.
2349