Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 2083

For ex series ethernet switches
Table of Contents

Advertisement

Required Privilege
Level
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
detection-time threshold milliseconds
detection time adapts to a value equal to or greater than the threshold, a single trap
and a single system log message are sent.
minimum-interval milliseconds
routing device transmits a hello packet and then expects to receive a reply from the
neighbor with which it has established a BFD session.
Range: 1 through 255,000
minimum-receive-interval milliseconds
the local routing device expects to receive a reply from a neighbor with which it has
established a BFD session.
Range: 1 through 255,000
—Configure the number of hello packets not received by a neighbor
multiplier number
that causes the originating interface to be declared down.
Range: 1 through 255
Default: 3
no-adaptation
—Specify that BFD sessions not adapt to changing network conditions.
We recommend that you not disable BFD adaptation unless it is preferable not to
have BFD adaptation enabled in your network.
transmit-interval threshold milliseconds
transmit interval adapts to a value greater than the threshold, a single trap and a
single system log message are sent. The interval threshold must be greater than the
minimum transmit interval.
Range: 0 through 4,294,967,295 (2
transmit-interval minimum-interval milliseconds
at which the routing device sends hello packets to a neighbor with which it has
established a BFD session.
Range: 1 through 255,000
—Specify the BFD version to detect.
version
Range:
(BFD version 1), or
1
Default:
automatic
The remaining statements are explained separately.
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring BFD for IS-IS
Configuring BFD Authentication for IS-IS
Chapter 79: Configuration Statements for Layer 3 Protocols
—Configure a threshold. When the BFD session
—Configure the minimum intervals at which the local
—Configure only the minimum interval at which
—Configure a threshold. When the BFD session
32
– 1)
—Configure only the minimum interval
(autodetection)
automatic