graceful-restart {
disable;
helper-disable;
restart-duration seconds;
}
[edit logical-systems logical-system-name protocols isis],
[edit protocols isis]
Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Configure graceful restart for IS-IS.
—Disable graceful restart.
disable
—Disable graceful restart helper capability. Helper mode is enabled by
helper-disable
default.
restart-duration seconds
—Configure the time period for the restart to last, in seconds.
Range: 30 through 300 seconds
Default: 30 seconds
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring Graceful Restart
Configuring Graceful Restart for IS-IS
Copyright © 2010, Juniper Networks, Inc.