1.10 Item 2.
Enter dC330 code 10-065 vacuum transport fan, MOT10-065. Figure 3. Press Start, The
runs.
Y
N
Go to Flag 2. Check MOT10-065. Refer to:
GP 10 How to Check a Motor.
Figure 3.
P/J5, IOT PWB.
P/J17, LVPS.
Fuse, PL 1.10 Item 9, GP 7.
01G +24V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Short paper path assembly, PL 10.25 Item 1.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 04-010 main drive motor. Press Start. Add code 08-070 registration clutch,
CL08-070. Press Start.
NOTE: The clutch will switch off after 5 seconds.
The jam clearance knob 4c, PL 8.15 Item 10, rotates.
Y
N
Go to Flag 3. Check CL08-070. Refer to:
GP 12 How to Check a Solenoid or Clutch.
P/J5, IOT PWB.
P/J17, LVPS.
Fuse, PL 1.10 Item 9, GP 7.
01G +24V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Registration clutch, (32-55 ppm) PL 8.15 Item 7.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 08-150 registration sensor, Q08-150. Press Start. Manually actuate the sen-
sor Figure 2. The display changes.
Y
N
Go to Flag 4. Check Q08-150. Refer to:
GP 11 How to Check a Sensor.
Figure 2.
P/J5, IOT PWB.
01D +3.3V Distribution RAP.
01B 0V Distribution RAP.
B
Status Indicator RAPs
10-101A, 10-102A, 10-103A
B
Install new components as necessary:
Registration sensor, (32-55 ppm) PL 8.15 Item 3.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
fan
1.10 Item 2.
Check the following components, refer to GP 7:
Registration roll, PL 8.15 Item 9.
Roll assembly on the short paper path assembly, PL 10.25 Item 1.
Check the detack corotron and the connection to the HVPS. Refer to 09-060 HVPS Fault
RAP
The drive gear on the fuser module, (32-55 ppm) PL 10.8 Item 1.
The fuser drive gear on the main drives module, (32-55 ppm) PL 4.17 Item 10.
Fuser web motor and the fuser web, 10A Fuser Web Motor RAP.
If the fault still occurs, check the drives plate on the registration clutch for damage and
contamination. Refer to the replacement procedure in REP 8.5.