A
•
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 10-065 vacuum transport fan, MOT10-065. Figure 3. Press Start, The
runs.
Y
N
Go to Flag 2. Check MOT10-065. Refer to:
•
GP 10 How to Check a Motor.
•
Figure 3.
•
P/J5, IOT PWB.
•
P/J17, LVPS.
•
Fuse, PL 1.10 Item 9, GP 7.
•
01G +24V Distribution RAP.
•
01B 0V Distribution RAP.
Install new components as necessary:
•
Short paper path assembly, PL 10.25 Item 1.
•
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 04-010 main drive motor. Press Start. Add code 08-070 registration clutch,
CL08-070. Press Start.
NOTE: The clutch will switch off after 5 seconds.
The jam clearance knob 4c, PL 8.15 Item 10, rotates.
Y
N
Go to Flag 3. Check CL08-070. Refer to:
•
GP 12 How to Check a Solenoid or Clutch.
•
P/J5, IOT PWB.
•
P/J17, LVPS.
•
Fuse, PL 1.10 Item 9, GP 7.
•
01G +24V Distribution RAP.
•
01B 0V Distribution RAP.
Install new components as necessary:
•
Registration clutch, (32-55 ppm) PL 8.15 Item 7.
•
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 08-150 registration sensor, Q08-150. Press Start. Manually actuate the sen-
sor Figure 2. The display changes.
Y
N
Go to Flag 4. Check Q08-150. Refer to:
•
GP 11 How to Check a Sensor.
•
Figure 2.
•
P/J5, IOT PWB.
•
01D +3.3V Distribution RAP.
•
01B 0V Distribution RAP.
B
Status Indicator RAPs
10-101A, 10-102A, 10-103A
B
Install new components as necessary:
•
Registration sensor, (32-55 ppm) PL 8.15 Item 3.
•
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
fan
1.10 Item 2.
Check the following components, refer to GP 7:
•
Registration roll, PL 8.15 Item 9.
•
Roll assembly on the short paper path assembly, PL 10.25 Item 1.
•
Check the detack corotron and the connection to the HVPS. Refer to 09-060 HVPS Fault
RAP
•
The drive gear on the fuser module, (32-55 ppm) PL 10.8 Item 1.
•
The fuser drive gear on the main drives module, (32-55 ppm) PL 4.17 Item 10.
•
Fuser web motor and the fuser web, 10A Fuser Web Motor RAP.
•
If the fault still occurs, check the drives plate on the registration clutch for damage and
contamination. Refer to the replacement procedure in REP 8.5.
August 2007
2-254
WorkCentre 5687 Family