09-341, 09-342 Scorotron Cleaning Failure RAP

09-341 The scorotron cleaning routine has failed to complete.
09-342 A scorotron cleaning warning detected.
Initial Actions
Check that the xerographic module is correctly installed.
Check the scorotron cleaner drive coupling, Figure 1.
Procedure
Enter dC330 code 09-071 or 09-072 scorotron cleaner motor. A clicking sound is heard.
Y
N
Go to Flag 2. Check MOT09-043. Refer to:
GP 10 How to Check a motor.
P/J64, IOT PWB.
01G +24V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Main drive module, (32-55 ppm) PL 4.15 Item 1, (65-87 ppm) PL 4.10 Item 1.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 09-070 scorotron cleaner home sensor, Figure 2. Press Start. Enter dC330
code 09-071 or 09-072 scorotron motor. Actuate the sensor by entering the appropriate code.
The display changes.
Y
N
Go to Flag 1. Check Q09-070. Refer to:
GP 13 How to Check a Switch.
NOTE: The scorotron cleaner home sensor is a magnetic reed switch.
P/J64, IOT PWB.
01D +3.3V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Scorotron cleaner home sensor, (45-55 ppm) PL 4.17 Item 16, (65-87 ppm) PL 4.12
Item 19.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
The fault may be intermittent, perform the following:
Check the wiring, GP 7. Repair if necessary, REP 1.2.
Ensure that P/J64 is correctly and securely connected.
WorkCentre 5687 Family
Scorotron cleaner home sensor
Figure 1 Component location
August 2007
2-237
Scorotron cleaner motor
Drive
coupling
Status Indicator RAPs
09-341, 09-342