Trail Edge Late From Inverter Sensor Rap - Xerox WorkCentre 5687 Series Service Manual

Table of Contents

Advertisement

10-135, 10-136, 10-137, 10-138 Trail edge Late from Inverter
Sensor RAP
10-135 The trail edge of the paper failed to de-actuate the inverter sensor within the correct
time, for a simplex non invert sheet.
10-136 The trail edge of the paper failed to de-actuate the inverter sensor within the correct
time, for a simplex inverted sheet.
10-137 The trail edge of the paper failed to de-actuate the inverter sensor within the correct
time, for a duplex sheet side 1.
10-138 The trail edge of the paper failed to de-actuate the inverter sensor within the correct
time, for a duplex sheet side 2.
WARNING
Do not touch the fuser while it is hot.
Initial Actions
Check the condition of the paper in all trays. Refer to IQ1 and GP 20.
NOTE: If the fault occurs only with heavy weight paper of 120 gsm (32 lb.) or greater that
are being inverted, enter the Tools Mode and Stock Settings. Change the stock type to
heavyweight for the appropriate tray. If the problem persists, perform the procedure in this
RAP.
Check for obstructions in the inverter area, Figure 1.
Check the upper and lower gravity fingers in the inverter, Figure 3, GP 7.
Check for obstructions in the exit area.
If the fault is caused by a multifeed of sheets, go to OF8 Multifeed RAP.
Procedure
WARNING
Take care during this procedure. Motors will become hot during normal operation.
NOTE: Ensure that the door interlock switch is cheated when checking +24V components.
Enter dC330 code 10-105 inverter sensor, Q10-105. Press Start. Manually actuate the sensor.
The display changes.
Y
N
Go to Flag 1. Check Q10-120. Refer to:
GP 11 How to Check a Sensor.
Figure 3.
P/J61, IOT PWB.
01E +5V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Inverter sensor, PL 10.12 Item 19.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
A
Status Indicator RAPs
10-135, 10-136, 10-137, 10-138
A
Enter dC330 code 10-050 inverter nip solenoid, SOL10-050. Press Start. The solenoid ener-
gises.
Y
N
Go to Flag 2. Check SOL10-050. Refer to:
GP 12 How to Check a Solenoid or Clutch.
Figure 1.
P/J5, IOT PWB.
P/J17, LVPS.
Fuse, PL 1.10 Item 9, GP 7.
01G +24V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Inverter nip solenoid, PL 10.11 Item 6.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 10-045 inverter path solenoid, SOL 10-045. Press Start. The
energizes.
Y
N
Go to Flag 3. Check SOL 10-045. Refer to:
GP 12 How to Check a Solenoid or Clutch.
Figure 1.
P/J5, IOT PWB
P/J17, LVPS.
Fuse, PL 1.10 Item 9, GP 7.
01G +24V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Inverter path solenoid, PL 10.11 Item 14.
Perform OF7 IOT PWB Diagnostics RAP before a new IOT PWB is installed, PL
1.10 Item 2.
Enter dC330 code 10-055 tri-roll nip split solenoid, SOL 10-055. Press Start. The
energizes.
Y
N
Go to Flag 5. Check SOL 10-055. Refer to:
GP 12 How to Check a Solenoid or Clutch.
Figure 3.
P/J61, IOT PWB
P/J17, LVPS.
Fuse, PL 1.10 Item 9, GP 7.
01G +24V Distribution RAP.
01B 0V Distribution RAP.
Install new components as necessary:
Tri-roll nip split solenoid, PL 10.14 Item 1.
B
August 2007
2-270
solenoid
solenoid
WorkCentre 5687 Family

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wc5632fWc5545fWc5675fWc5645fWc5687fWc5655f

Table of Contents