4.2.5 Configuring ELPS fault detection mode

Configure the ELPS fault detection mode for the ISCOM2600G-HI series switch as below.
1
2
Fault detection modes of the working line and protection line can be different.
However, we recommend keeping fault detection mode configurations of the working
line and protection line consistent.

4.2.6 (Optional) configuring ELPS control

Configure ELPS control for the ISCOM2600G-HI series switch as below.
Command
Raisecom(config)#ethernet
line-protection trap enable
Step
Raisecom#config
Raisecom(config)#ethernet line-
protection
protection } failure-detect
physical-link
Raisecom(config)#ethernet line-
protection
protection } failure-detect cc
md-name
[ md
level
local
mep
mep-id
Raisecom(config)#ethernet line-
protection
protection } failure-detect
physical-link-or-cc [ md
name
] ma
ma-name
local
mep-id remote
mep
-
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Command
line-id
{ working |
line-id
{ working |
ma-name
] ma
level
mep-id remote
-
line-id
{ working |
md-
level
level
mep-id
-
4 Ring network protection
Description
(Optional) enable ELPS Trap to be
reported to the NMS.
By default, ELPS Trap to be reported to
the NMS is disabled.
Use the ethernet line-protection trap
disable command to disable ELPS Trap.
Description
Enter global configuration mode.
Configure the fault detection mode
of the working line/protection line to
physical link.
By default, it is physical link.
Configure the fault detection mode
of the working line/protection line to
CC.
This fault detection mode cannot
-
take effect unless you finish related
configurations on CFM.
Configure the fault detection mode
of the working line/protection line to
failure-detect physical-link-or-cc.
In this mode, a Trap is reported
when a fault is detected on the
physical link/CC.
This fault detection mode cannot
take effect unless you finish related
configurations on CFM.