Default Configurations Of Elps; Creating Elps Pair - Raisecom ISCOM2600G-HI (A) Series Configuration Manual

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
This ISCOM2600G-HI series switch does not distinguish one-way and bidirectional switching
until in 1+1 mode; only bidirectional switching is available in 1:1 mode.
ELPS provides two modes for fault detection:
Prerequisite

4.2.3 Default configurations of ELPS

Default configurations of ELPS are as below.
Protection group mode
WTR timer
Hold-off timer
Reporting ELPS failure information to network management system
Fault detection mode

4.2.4 Creating ELPS pair

Enable the ELPS pair for the ISCOM2600G-HI series switch as below.
Step
1
detects a fault and switches the traffic. And the other end does not detect the fault and
switch traffic. Therefore, both ends may receive the traffic through different lines.
Bidirectional switching: when a line fails, even in one direction, both ends communicate
through APS protocol to switch traffic to the protection line. Therefore, both ends receive
and send the traffic through the same line.
Detecting fault over physical interface status: to get link fault quickly and switching in
time, available to neighboring devices.
Detecting fault over CC: available to one-way detection or multi-devices crossing
detection.
Connect interfaces.
Configure physical parameters to make interfaces Up at the physical layer.
Create VLANs.
Add interfaces to VLANs.
Configure CFP detection among devices and make them as neighbors (for CFM
detection mode only).
Command
Raisecom#config
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Function
Enter global configuration mode.
4 Ring network protection
Default value
Revertive mode
5min
0
Enable
Physical link
Description
200