10
You can enable/disable alarm monitoring, alarm auto-reporting, and alarm clearing on
modules that support alarm management.

12.6.4 Checking configurations

Use the following commands to check configuration results.
1
2
3
4

12.7 Hardware environment monitoring

The ISCOM2624G-4GE-HI and ISCOM2608G-2GE-HI adopt fanless design, so they
do not support abnormal temperature alarm. For details, see their descriptions.

12.7.1 Introduction

Hardware environment monitoring mainly refers to monitor the running environment of the
ISCOM2600G-HI series switch. The monitoring alarm events include:
Step
Raisecom(config)#alarm syslog
enable
Raisecom(config)#exit
Raisecom#show alarm active
module_name
[
Raisecom#show alarm cleared
[
module_name
No.
Command
Raisecom#show alarm
management
alarm_type
[
Raisecom#show alarm
log
Raisecom#show alarm
management
statistics
Raisecom#show alarm
active
Power supply state alarm
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Command
severity
| severity
| severity
severity
Show parameters of current alarms, including
status of alarm suppression, alarm reverse mode,
]
alarm delay, and alarm storage mode, maximum
alarm buffer size, and alarm log size.
Show alarm statistics in the system log.
Show statistics about alarm management module.
Show information about current alarms.
12 System management
Description
(Optional) enable alarms to be
output to system logs.
By default, it is disabled.
(Optional) show information
about current alarms.
]
(Optional) show information
]
about historical alarms.
Description
524

Advertisement

Table of Contents
loading

Table of Contents

Save PDF