Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
12.7.5 Configuring temperature monitoring alarm
Configure temperature monitoring alarm for the ISCOM2600G-HI series switch as below.
1
2
3
12.7.6 Configuring power supply alarm
Configure voltage monitoring alarm for the ISCOM2600G-HI series switch as below.
1
2
12.7.7 Clearing all hardware environment monitoring alarms
manually
Clear all hardware environment monitoring alarms manually for the ISCOM2600G-HI series
switch as below.
When enabling global hardware environment monitoring alarm Syslog output,
alarm event can generate Syslog only when Syslog output under alarm event is
also enabled.
When enabling global hardware environment monitoring alarm sending Trap,
alarm event can send Trap only when Trap output under alarm event is also
enabled.
Step
Command
Raisecom#config
Raisecom(config)#
alarm temperature
{ notifies |
syslog }
Raisecom(config)#
alarm temperature
high
{ high
low
| low
-
notifies |
syslog }
Step
Raisecom#config
Raisecom(config)# alarm
power-supply { notifies |
syslog }
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Enter global configuration mode.
Enable abnormal temperature alarm.
Enable temperature monitoring alarm output and
configure temperature monitoring alarm output
value
-
modes.
value
|
The high temperature threshold (high-value) must
be greater than the low temperature threshold (low-
value).
The low temperature threshold (low-value) must be
smaller than the high temperature threshold (high-
value).
Command
12 System management
Description
Description
Enter global configuration mode.
Enable power supply alarm and
configure alarm output mode.