Raisecom ISCOM2600G-HI (A) Series Configuration Manual page 500

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
Raisecom(config-gigaethernet1/1/2)#port backup gigaethernet 1/1/1
vlanlist 151-200
Checking results
Use the show port backup group command to show status of interface backup under normal
or faulty conditions.
When both GE 1/1/1 and GE 1/1/2 are Forward, GE 1/1/1 forwards traffic of VLANs 100–
150, and GE 1/1/2 forwards traffic of VLANs 151–200.
Raisecom#show port backup group
Active Port(State)
-------------------------------------------------------------------------
-------------------------------------
GE1/1/1(Forward)
GE1/1/2(Forward)
Manually disconnect the link between Switch A and Switch B to emulate a fault. Then, GE
1/1/1 becomes Down, and GE 1/1/2 forwards traffic of VLANs 100–200.
Raisecom#show port backup group
Active Port(State)
-------------------------------------------------------------------------
-------------------------------------
GE1/1/1(Down)
GE1/1/2(Forward)
When GE 1/1/1 resumes and keeps Forward for 15s (restore-delay), it forwards traffic of
VLANs 100–150 while GE 1/1/2 forwards traffic of VLANs 151–200.
Raisecom#show port backup group
Active Port(State)
-------------------------------------------------------------------------
-------------------------------------
GE1/1/1(Forward)
GE1/1/2(Forward)
Backup Port(State)
GE1/1/2(Block)
GE1/1/1(Block)
Backup Port(State)
GE1/1/2(Forward)
GE1/1/1(Down)
Backup Port(State)
GE1/1/2(Block)
GE1/1/1(Block)
Raisecom Proprietary and Confidential