Preparing For Configurations; Configuring Basic Functions Of Alarm Management - Raisecom ISCOM2600G-HI (A) Series Configuration Manual

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
Use configured storage mode to deal with new generated alarm when the alarm in device
alarm table is full.
Clear the current alarm, which means deleting current alarms from the current alarm table.
The cleared alarms will be saved to the history alarm table.
The administrator can check alarms and monitor alarm directly on the ISCOM2600G-HI
series switch. If the ISCOM2600G-HI series switch is configured with NView NNM system,
the administrator can monitor alarms on the NView NNM system.

12.6.2 Preparing for configurations

Scenario
When the device fails, alarm management module will collect fault information and output
alarm occurrence time, alarm name and description information in log format to help users
locate problem quickly.
If the device is configured with the NMS, alarm can be reported directly to the NMS,
providing possible alarm causes and treatment recommendations to help users deal with fault.
If the device is configured with hardware monitoring, it will record the hardware monitoring
alarm table, generated Syslog, and sent Trap when the operation environment of the device
becomes abnormal, and notify the user of taking actions accordingly and prevent faults.
Alarm management facilitates alarm suppression, alarm auto-reporting, alarm monitoring,
alarm reverse, alarm delay, alarm memory mode, alarm clear and alarm view directly on the
device.
Prerequisite
Hardware environment monitoring alarm output:

12.6.3 Configuring basic functions of alarm management

Configure basic information of alarm management for the ISCOM2600G-HI series switch as
below.
All following steps are optional and no sequence between them.
1
2
3
Clearing alarms
Viewing alarms
In Syslog output mode: alarms will be generated into system logs. To send alarm to the
system log host, configure the IP address of the system log host for the device.
In Trap output mode: configure the IP address of the NMS for the device.
Step
Raisecom#config
Raisecom(config)#alarm inhibit
enable
Raisecom(config)#alarm auto-report
all enable
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Command
12 System management
Description
Enter global configuration
mode.
Enable alarm suppression.
By default, it is enabled.
Enable alarm auto-reporting.
522