Raisecom ISCOM2600G-HI (A) Series Configuration Manual page 236

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
Step 2 Create a 1:1 mode ELPS pair.
Configure Switch A.
SwitchA(config)#ethernet line-protection 1 working gigaethernet 1/1/1
100-200 protection gigaethernet 1/1/2 100-200 one-to-one
Configure Switch B.
SwitchB(config)#ethernet line-protection 1 working gigaethernet 1/1/1
100-200 protection gigaethernet 1/1/2 100-200 one-to-one
Step 3 Configure fault detection mode.
Configure Switch A.
SwitchA(config)#ethernet line-protection 1 working failure-detect
physical-link
SwitchA(config)#ethernet line-protection 1 protection failure-detect
physical-link
Configure Switch B.
SwitchB(config)#ethernet line-protection 1 working failure-detect
physical-link
SwitchB(config)#ethernet line-protection 1 protection failure-detect
physical-link
Checking results
Use the show ethernet line-protection command to show configurations of 1:1 ELPS on the
ISCOM2600G-HI series switch.
Take Switch A for example.
SwitchA#show ethernet line-protection 1
Trap State:Enable
Id:1
Name:--
ProtocolVlan:1
Working Entity Information:
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
4 Ring network protection