Raisecom ISCOM2600G-HI (A) Series Configuration Manual page 415

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
SwitchC(config-gigaethernet1/1/2)#switch access vlan 100
SwitchC(config-gigaethernet1/1/2)#exit
SwitchC(config)#interface gigaethernet 1/1/1
SwitchC(config-gigaethernet1/1/1)#switchport mode trunk
SwitchC(config-gigaethernet1/1/1)#exit
Step 2 Configure CFM fault detection.
Configure Switch A.
SwitchA(config)#ethernet cfm domain level 3
SwitchA(config)#service ma1 level 3
SwitchA(config-service)#service vlan-list 100
SwitchA(config-service)#service mep up mpid 301 gigaethernet 1/1/1
SwitchA(config-service)#service remote-mep 302
SwitchA(config-service)#service cc enable mep all
SwitchA(config-service)#exit
SwitchA(config)#ethernet cfm enable
Configure Switch B.
SwitchB(config)#ethernet cfm domain level 3
SwitchB(config)#service ma1 level 3
SwitchB(config-service)#service vlan-list 100
SwitchB(config-service)#exit
SwitchB(config)#ethernet cfm enable
Configure Switch C.
SwitchC(config)#ethernet cfm domain level 3
SwitchC(config)#service ma1 level 3
SwitchC(config-service)#service vlan-list 100
SwitchC(config-service)#service mep up mpid 302 gigaethernet 1/1/2
SwitchC(config-service)#service remote mep 301
SwitchC(config-service)#service cc enable mep all
SwitchC(config-service)#exit
SwitchC(config)#ethernet cfm enable
Step 3 Execute CFM fault acknowledgement.
Take Switch A for example.
Switch(config)#service ma1 level 3
Switch(config-service)#ping mep 302 source 301
Raisecom Proprietary and Confidential