Configuring Erps Fault Detection Mode - Raisecom ISCOM2600G-HI (A) Series Configuration Manual

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
Step
5
6
7

4.1.5 Configuring ERPS fault detection mode

Configure the ERPS fault detection mode for the ISCOM2600G-HI series switch as below.
Step
1
2
Command
Raisecom(config)#ethernet
ring-id
ring-protection
guard-time
guard-time
Raisecom(config)#ethernet
ring-id
ring-protection
wtr-time
time
Raisecom(config)#ethernet
ring-id
ring-protection
holdoff-time
holdoff-time
Command
Raisecom#config
Raisecom(config)#ethernet ring-
protection
ring-id
failure-detect physical-link
Raisecom(config)# ethernet ring-
protection
ring-id
failure-detect cc [ md
ma-name
level
level
remote
mep-id
-
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
(Optional) after the ring Guard timer is
configured, the failed node does not
process APS packets during a period. In a
bigger ring network, if the failed node
recovers from a fault immediately, it may
receive the fault notification sent by the
neighbor node on the protection ring.
Therefore, the node is in Down status
again. You can configure the ring Guard
timer to solve this problem.
(Optional) configure the ring WTR timer.
wtr-
In revertive mode, when the working line
recovers from a fault, traffic is not
switched to the working line unless the
WTR timer times out.
(Optional) configure the ring Hold-off
timer. After the Hold-off timer is
configured, when the working line fails,
the system will delay processing the
fault. It means that traffic is delayed to be
switched to the protection line. This
helps prevent frequent switching caused
by working line vibration.
If the ring Hold-off timer value is too
great, it may influence 50ms
switching performance. Therefore,
we recommend configuring the ring
Hold-off timer value to 0.
{ east | west }
{ east | west }
md-name
] ma
local
mep-id
mep
-
4 Ring network protection
Description
Description
Enter global configuration mode.
Configure the ERPS fault
detection mode to physical link.
By default, it is physical link.
Configure the ERPS fault
detection mode to CFM.
195

Advertisement

Table of Contents
loading

Table of Contents