Configuring Bfd Session Parameters - Raisecom ISCOM2600G-HI (A) Series Configuration Manual

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
3

9.5.4 Configuring BFD session parameters

Configure BFD session parameters for the ISCOM2600G-HI series switch as below.
1
2
3
4
5
6
7
Step
Raisecom(config)#bfd trap
{ enable | disable }
Step
Command
Raisecom#config
Raisecom(config)#bfd
session-id
Raisecom(config)#bfd
{ detect-multiplier
multiplier
receive-interval
interval
| send-
interval
interval
Raisecom(config-bfd-
session)#description
description
Raisecom(config-bfd-
session)#local
discriminator
Raisecom(config-bfd-
session)#min send-
interval
interval
Raisecom(config-bfd-
session)#min
receive-interval
interval
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Command
Enter global configuration mode.
Enter BFD session mode.
You cannot use this command to enter BFD
session mode until you create the BFD and
bind it with the related path.
Configure the local detection multiplier, minimum
sending interval, and minimum receiving interval
|
for dynamic BFD sessions globally or on the
interface.
}*
Configure them globally for the multi-hop IP
address. Configure them on the interface for
single IP address or default IP address.
Configure the description of the BFD session.
Configure the local identifier of the BFD session.
By default, the local identifier is displayed as 0,
value
which indicates that no local identifier is
configured.
The local identifier is automatically
generated by the system if not configured.
Configure the minimum sending interval for the
BFD session.
By default, it is 1000ms.
Configure the minimum receiving interval of the
BFD session.
By default, it is 1000ms.
Description
(Optional) enable BFD Trap.
By default, it is disabled.
Description
9 OAM
395

Advertisement

Table of Contents
loading