There are several ways to notify users when an alarm is generated. The alarm event output
methods are as below:
You can take appropriate measures to prevent failure when alarm events happen.
Alarm events
Power supply state change refers that unplugged power supply is plugged into the device and
vice versa. The ISCOM2600G-HI series switch supports dual power supplies. Therefore,
power supply state change alarms are divided into the single power supply state change alarm
and device dying gasp alarm.
The device supports temperature beyond threshold alarm event, when the current temperature
is lower than low temperature threshold, the low temperature alarm event will generate. The
ISCOM2600G-HI series switch supports saving to the device hardware environment
monitoring alarm buffer, sending Trap to the NView NNM system, and outputting to the
system log and relay.
When the device current temperature is higher than high temperature threshold, the high
temperature alarm event will generate. The ISCOM2600G-HI series switch supports saving to
the device hardware environment monitoring alarm buffer, sending Trap to the NView NNM
system, and outputting to the system log and relay.
Alarm output modes
Hardware environment monitoring alarm output modes are as below.
Temperature beyond threshold alarm
Flash monitoring alarm
Save to the device hardware environment monitoring alarm buffer.
Output Syslog system log.
Send Trap to the NMS.
Power supply monitoring alarms
Power supply state change alarms
Dual power supply state change alarm: notify uses that power supply 1/power supply
2 changes. The ISCOM2600G-HI series switch supports saving to the device
hardware environment monitoring alarm buffer, sending Trap to the NView NNM
system, and outputting to the system log and relay.
Device dying gasp alarm: dual power modules are unplugged, in other words, two
power modules are out of position. The ISCOM2600G-HI series switch supports
saving to the device hardware environment monitoring alarm buffer, sending Trap to
the NView NNM system, and outputting to the system log and relay.
Temperature beyond threshold alarm
Hardware environment monitoring alarm buffer output, which is recorded to the
hardware environment monitoring alarm table
The hardware environment monitoring current alarm table, recording current alarm
which has not been cleared and restored.
The hardware environment monitoring history alarm table, recording current, restored,
and manually cleared alarms.