Preparing For Configurations; Default Configurations Of Optical Module Ddm; Enabling Optical Module Ddm - Raisecom ISCOM2600G-HI (A) Series Configuration Manual

Table of Contents

Advertisement

Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
The performance parameters of optical module which are monitored by optical module DDM
are as below:
When the performance parameters reach alarm threshold or status information changes, the
corresponding Trap alarm will be generated.

12.4.2 Preparing for configurations

Scenario
Fault diagnostics f optical modules provide a method for detecting SFP performance
parameters. You can predict the service life of optical module, isolate system fault and check
its compatibility during installation through analyzing monitoring data.
Prerequisite
The optical module used on the ISCOM2600G-HI series switch should be a Raisecom-
certified one. If you use an optical module of other vendors, problems of unstable services,
failure in supporting DDM, or incorrect DDM information will happen.

12.4.3 Default configurations of optical module DDM

Default configurations of optical module DDM are as below.
Global optical module DDM
Interface optical module DDM
Global optical DDM Trap
Interface optical DDM Trap

12.4.4 Enabling optical module DDM

Enable optical module DDM for the ISCOM2600G-HI series switch as below.
1
2
3
Modular temperature
Inner power voltage
Tx offset current
Tx optical power
Rx optical power
Function
Step
Command
Raisecom#config
Raisecom(config)#trans
ceiver ddm enable
Raisecom(config)#trans
ceiver ddm poll-
interval
interval
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Default value
Disable
Disable
Disable
Disable
Description
Enter global configuration mode.
Enable optical module DDM globally.
Configure the polling interval for optical module
DDM.
12 System management
510

Advertisement

Table of Contents
loading

Table of Contents